ULTRAOX PSA oxygen generators come in 16 sizes, from 3.10 Nm³/h of oxygen on ULTRAOX 30 to 165.3 Nm³/h on ULTRAOX 1640. Find your flow in the table, and Ultra Controlo engineers confirm the configuration for your site.
Each model is listed with its oxygen flow in Nm³/h, the normal cubic metres per hour. ULTRAOX SC and ULTRAOX ST have the same 16 models, oxygen flows and ULTRACON generators.
Simplex layout. Same oxygen capacity in all three altitude bands. Indicative, from the datasheet. Our engineers confirm the configuration for your site. ULTRAOX 520, 730, 1120 and 1640 have two ULTRACON generators of the same model, written × 2.
| Model | Oxygen, Nm³/h | Max. daily filling capacity, cylinders (50 L @ 150 bar) | Oxygen generator |
|---|---|---|---|
| ULTRAOX 30 | 3.10 | 10 | ULTRACON 4 |
| ULTRAOX 50 | 4.60 | 14 | ULTRACON 5 |
| ULTRAOX 70 | 6.50 | 20 | ULTRACON 6 |
| ULTRAOX 90 | 8.00 | 25 | ULTRACON 7 |
| ULTRAOX 100 | 9.50 | 30 | ULTRACON 8 |
| ULTRAOX 120 | 12.4 | 40 | ULTRACON 9 |
| ULTRAOX 180 | 18.2 | 58 | ULTRACON 10 |
| ULTRAOX 260 | 26.2 | 84 | ULTRACON 11 |
| ULTRAOX 370 | 36.5 | 116 | ULTRACON 12 |
| ULTRAOX 440 | 43.5 | 139 | ULTRACON 13 |
| ULTRAOX 520 | 52.4 | 168 | ULTRACON 11 × 2 |
| ULTRAOX 560 | 55.7 | 178 | ULTRACON 14 |
| ULTRAOX 730 | 73.0 | 232 | ULTRACON 12 × 2 |
| ULTRAOX 820 | 82.7 | 264 | ULTRACON 15 |
| ULTRAOX 1120 | 111.4 | 356 | ULTRACON 14 × 2 |
| ULTRAOX 1640 | 165.3 | 528 | ULTRACON 15 × 2 |
Each model has its compressor size for three altitude bands: 0 to 1,000 m, 1,000 to 2,000 m and 2,000 to 3,000 m. The compressor is an ULTRASCREW VSD.
The oxygen flow of a model is the same in all three bands. At 2,000 to 3,000 m, ULTRAOX 1640 uses 2 × ULTRASCREW 160, with 2 oxygen filtration systems and 2 flow measurement systems.
| Model | 0 to 1,000 m | 1,000 to 2,000 m | 2,000 to 3,000 m |
|---|---|---|---|
| ULTRAOX 30 | ULTRASCREW 5 | ULTRASCREW 7 | ULTRASCREW 7 |
| ULTRAOX 50 | ULTRASCREW 7 | ULTRASCREW 11 | ULTRASCREW 11 |
| ULTRAOX 70 | ULTRASCREW 11 | ULTRASCREW 15 | ULTRASCREW 15 |
| ULTRAOX 90 | ULTRASCREW 15 | ULTRASCREW 18 | ULTRASCREW 18 |
| ULTRAOX 100 | ULTRASCREW 18 | ULTRASCREW 18 | ULTRASCREW 18 |
| ULTRAOX 120 | ULTRASCREW 18 | ULTRASCREW 22 | ULTRASCREW 30 |
| ULTRAOX 180 | ULTRASCREW 30 | ULTRASCREW 37 | ULTRASCREW 37 |
| ULTRAOX 260 | ULTRASCREW 37 | ULTRASCREW 45 | ULTRASCREW 55 |
| ULTRAOX 370 | ULTRASCREW 55 | ULTRASCREW 75 | ULTRASCREW 75 |
| ULTRAOX 440 | ULTRASCREW 75 | ULTRASCREW 75 | ULTRASCREW 75 |
| ULTRAOX 520 | ULTRASCREW 75 | ULTRASCREW 90 | ULTRASCREW 110 |
| ULTRAOX 560 | ULTRASCREW 75 | ULTRASCREW 110 | ULTRASCREW 110 |
| ULTRAOX 730 | ULTRASCREW 110 | ULTRASCREW 132 | ULTRASCREW 160 |
| ULTRAOX 820 | ULTRASCREW 132 | ULTRASCREW 160 | ULTRASCREW 160 |
| ULTRAOX 1120 | ULTRASCREW 160 | ULTRASCREW 200 | ULTRASCREW 200 |
| ULTRAOX 1640 | ULTRASCREW 250 | ULTRASCREW 315 | 2 × ULTRASCREW 160 |
ULTRAOX SC, ST and CO share the same PSA oxygen generators and differ in how the air is compressed and where the plant is housed.
ULTRAOX SC uses oil-less ULTRACECO compressors. ULTRAOX ST uses ULTRASCREW rotary screw compressors. ULTRAOX CO is a complete plant built inside a shipping container, for sites with no technical room or no space for civil works.
To size a plant, Ultra Controlo needs the oxygen flow required in m³/h or, for cylinder filling, the size and number of cylinders to fill per day.
Send the oxygen flow you need in m³/h, or use the table above to find the closest size.
If the plant will also fill cylinders, give the cylinder size and how many cylinders a day.
Heat, humidity, dust, altitude and the power supply all change what a PSA plant needs, so give the manufacturer the real site conditions.
Questions hospitals ask us about on-site oxygen. More on the medical gas answers page.
ULTRAOX plant models range from 3.10 Nm³/h of oxygen on ULTRAOX 30 to 165.3 Nm³/h on ULTRAOX 1640, delivered at 5 to 6 bar; each plant has one or two ULTRACON generators.
There are 16 models, listed in the table above with their oxygen flow, daily cylinder filling and ULTRACON generator.
The datasheet table has no model at exactly 30 or 60 Nm³/h. It lists ULTRAOX 260 at 26.2 Nm³/h and ULTRAOX 370 at 36.5 Nm³/h, and ULTRAOX 560 at 55.7 Nm³/h and ULTRAOX 730 at 73.0 Nm³/h.
Indicative, from the datasheet. Our engineers confirm the configuration for your site.
ULTRAOX 1640 is listed at 165.3 Nm³/h of oxygen, with two ULTRACON 15 generators and a maximum daily filling capacity of 528 cylinders (50 L @ 150 bar).
Each model has its compressor size for three altitude bands: 0 to 1,000 m, 1,000 to 2,000 m and 2,000 to 3,000 m.
Same oxygen capacity in all three altitude bands.
The tables list a maximum daily filling capacity from 10 cylinders on ULTRAOX 30 to 528 cylinders on ULTRAOX 1640, for cylinders of 50 L @ 150 bar. See the PSA oxygen cylinder filling plant page.
Plants are modular: one or more generators and compressors are combined to match the hospital’s demand, and capacity can be added later without replacing what is already installed.
Email leads@ultra-controlo.com or call +351 219 154 350 with the gases you need, the site and the demand.
For oxygen, give the flow in m³/h or, for cylinder filling, the cylinder size and how many cylinders a day. Ultra Controlo’s engineering team sizes the system from those figures.
Tell us about your site. Our engineering team sizes the configuration and sends a quote.