Industrial
Medical Vacuum Systems
Medical Air Systems
Medical Oxygen Systems
Medical Equipments

ULTRAK

Activated Carbon Tower

ULTRAK

ULTRAK

Separates oil vapours from compressed air by adsorption, down to < 0.003 mg/m³.

ULTRAK activated carbon towers separate oil vapours and hydrocarbons from compressed air by adsorption (dry separation). They are made of steel, with internal flow distributors for even air passage through the carbon bed, and they are part of ULTRAOX ST oxygen plants.

Inquiry now

ULTRAK

Activated Carbon Tower

ULTRAK

ULTRAK

Separates oil vapours from compressed air by adsorption, down to < 0.003 mg/m³.

ULTRAK activated carbon towers separate oil vapours and hydrocarbons from compressed air by adsorption (dry separation). They are made of steel, with internal flow distributors for even air passage through the carbon bed, and they are part of ULTRAOX ST oxygen plants.

< 0.003mg/m³ residual oil vapour (nominal)
6 to 6,500Nm³/h at 7 bar(g), 20 °C
16bar operating pressure

Get the highlights.

ULTRAK activated carbon towers separate oil vapours and hydrocarbons from compressed air by adsorption (dry separation). They are made of steel, with internal flow distributors for even air passage through the carbon bed, and they are part of ULTRAOX ST oxygen plants.

Residual oil < 0.003 mg/m³

The activated carbon bed removes oil vapours to < 0.003 mg/m³ (nominal). Oil quality class 0/1 to ISO 8573-1 (compressed air: contaminants and purity classes).

Uniform air flow

Internal flow distributors ensure even air passage through the bed of activated carbon.

Service indicator

An oil-mist indicator signals when service is needed.

Filter pairing

Requires an upstream coalescing filter and a downstream 1 µm dust filter, to intercept any residue from the activated carbon.

Technical specifications.

Operating pressure
16 bar
Operating temperature
1.5 to 45 °C
Fitting diameters
3/8" to DN125
Volume flow
6 to 6,500 Nm³/h at 7 bar(g), 20 °C
Residual oil vapour
< 0.003 mg/m³ (nominal)
Quality class, oils
0/1 to ISO 8573-1 (compressed air: contaminants and purity classes)
Pressure drop, new and dry
20 mbar / 0.29 psi
Filter element
Charcoal
Standard colour
RAL 5012
Construction
Steel, internal flow distributors, oil-mist indicator
Versions
Stainless-steel and high-pressure versions available
Required filters
Coalescing filter upstream, 1 µm dust filter downstream

ULTRAK models

ModelSeriesFittingsOperating pressure barFlow Nm³/hscfmA × B × C mm
ULTRAK 1A3/8"1663.5404 × 188 × 100
ULTRAK 2A3/8"16127638 × 188 × 100
ULTRAK 3A3/8"162414.11,106 × 188 × 100
ULTRAK 4A3/8"163621.11,574 × 188 × 100
ULTRAK 5A1/2"166035.31,106 × 270 × 148
ULTRAK 6A1/2"167544.11,340 × 270 × 148
ULTRAK 7A1/2"1610561.81,808 × 270 × 148
ULTRAK 8B1"16110861,522 × 350 × 252
ULTRAK 9B1"161501171,766 × 350 × 252
ULTRAK 10B1"162001571,532 × 400 × 303
ULTRAK 11B1"162602041,784 × 400 × 303
ULTRAK 12B1 1/2"163202511,551 × 450 × 357
ULTRAK 13B1 1/2"164103211,798 × 450 × 357
ULTRAK 14B1 1/2"165904621,893 × 650 × 424
ULTRAK 15B2"167706031,877 × 650 × 468
ULTRAK 16B2"161,0007841,961 × 650 × 506
ULTRAK 17CDN50161,2009362,170 × 550 × 550
ULTRAK 18CDN65161,5001,1702,210 × 620 × 620
ULTRAK 19CDN65162,0001,5602,330 × 700 × 700
ULTRAK 20CDN80162,5001,9502,260 × 760 × 760
ULTRAK 21CDN80163,0002,3402,400 × 800 × 800
ULTRAK 22CDN100163,7502,9252,490 × 920 × 920
ULTRAK 23CDN100165,0003,9002,600 × 1,050 × 1,050
ULTRAK 24CDN125166,5005,0702,730 × 1,150 × 1,150

Volume flow at 7 bar(g), 20 °C.

Prefer a PDF?ULTRAK datasheet

Questions, answered.

What does ULTRAK remove?

Oil vapours and other hydrocarbons, by adsorption on a bed of activated carbon.

Which filters does it need?

An upstream coalescing filter and a downstream 1 µm dust filter.

What residual oil content can it reach?

< 0.003 mg/m³ (nominal), oil quality class 0/1 to ISO 8573-1.

Request a quote.

Tell us about your site. Our engineering team sizes the configuration and sends a quote.

Or write to leads@ultra-controlo.com

This opens your email app with the request ready to send to leads@ultra-controlo.com.

ULTRAK activated carbon towers separate oil vapours and hydrocarbons from compressed air by adsorption (dry separation). They are made of steel, with internal flow distributors for even air passage through the carbon bed, and they are part of ULTRAOX ST oxygen plants.
Separates oil vapours from compressed air by adsorption, down to < 0.003 mg/m³.
Activated Carbon Tower

Technical Specifications

Why buy from Ultra Controlo

Four decades of engineering, backed end-to-end.

Certified quality management

ISO 13485:2016 (medical devices: quality management systems) and ISO 9001:2015 (quality management systems).

UltraCare support

Preventive and corrective maintenance, original spare parts and technical assistance 24 hours a day, 7 days a week.

Sized by our engineers

Tell us how the system will be used, and our engineering team sizes it and sends a quote.

Shipped from Portugal

Ultra Controlo plants are assembled and tested in our factories in Portugal, ready to be installed on site.

Ultra Controlo White Logo

Who are we?

Ultra Controlo is formed by a dynamic and enterprising team dedicated to the manufacture of medical gas plants, assembled and tested in our factories and ready to be installed in clinics and hospitals everywhere around the world.

We supply complete turn-key projects, build to fit your needs, on Medical Gas Piping Systems (MGPS).

About Us