ULTRACECO HP and ULTRACECO HPT are oil-free high-pressure oxygen boosters for medical cylinder filling. They take PSA oxygen in at 2.5 to 4 bar and compress it to a maximum of 150 to 207 bar, depending on the model.
ULTRACECO HP covers 3.2 to 17.2 Nm³/h per booster at 150 to 207 bar. ULTRACECO HPT covers 5 to 50 Nm³/h per booster at 150 bar.
| Booster | ULTRACECO HP | ULTRACECO HPT |
|---|---|---|
| Models | HP2, HP3 and HP3S. Sets: HP3D, HP3SD, HP3T and HP3ST | HPT1 to HPT8. Sets: HPT1D to HPT8D and HPT1T to HPT8T |
| Capacity per booster | 3.2 Nm³/h on HP2, 17.2 Nm³/h on HP3 and HP3S | 5 to 50 Nm³/h |
| Outlet pressure | 150 bar on HP2, 172 bar on HP3, 207 bar on HP3S | 150 bar |
| Inlet pressure | 2.5 to 4 bar | 2.5 to 4 bar |
| Motor power per booster | 1.1 kW on HP2, 7.5 kW on HP3 and HP3S | 3 to 18.5 kW |
| Compression | Oil-free, for medical oxygen | Oil-free, for medical oxygen |
The filling rack is designed for clean tie-in to new or existing plants. Booster inlet pressure is 2.5 to 4 bar.
Preassembled manifolds, pressure-rated valves and stainless-steel flexibles enable quick commissioning and clean tie-in to new or existing plants.
An ULTRAFIL filling station connects to an ULTRAOX plant and fills medical oxygen cylinders using an ULTRACECO HP or ULTRACECO HPT high-pressure oxygen booster, at a maximum pressure of 150 to 207 bar depending on the model. The station has two components: the booster and a cylinder filling rack.
For medical oxygen, with automatic start and stop from the inlet pressure.
High temperature and overpressure shutdowns, with a star delta starter and hour counter.
Every size from HPT1 to HPT8 comes as a single booster, a D set of two or a T set of three.
Compact footprint for easy maintenance.
The two ULTRACECO boosters, the ULTRAFIL station that uses them, and the ULTRAOX plants that make the oxygen.
Oil-free booster for filling medical oxygen cylinders, at 150 to 207 bar by model.
View ULTRACECO HPOil-free booster for filling medical oxygen cylinders, 5 to 50 Nm³/h per booster at 150 bar.
View ULTRACECO HPTFilling station for racks of 5, 10 or 20 cylinders, at a maximum pressure of 150 to 207 bar depending on the model.
View ULTRAFILAn ULTRAOX plant makes the oxygen and an ULTRAFIL station fills it into medical oxygen cylinders.
View the filling plantQuestions hospitals ask us about on-site oxygen. More on the medical gas answers page.
ULTRACECO HP and ULTRACECO HPT compress PSA oxygen to high pressure for medical cylinder filling, with oil-free compression. They are the two boosters used in ULTRAFIL filling stations.
ULTRACECO HP covers 3.2 to 17.2 Nm³/h per booster at 150 to 207 bar. ULTRACECO HPT covers 5 to 50 Nm³/h per booster at 150 bar.
Every size from HPT1 to HPT8 comes as a single booster, a D set of two or a T set of three.
HP3 and HP3S come in D sets of two boosters and T sets of three. HP2 is single only.
Maximum outlet pressure is 150 bar on HP2 and every HPT model, 172 bar on HP3 and 207 bar on HP3S. Booster inlet pressure is 2.5 to 4 bar.
The filling rack is designed for clean tie-in to new or existing plants. Booster inlet pressure is 2.5 to 4 bar.
Motor power per booster is 1.1 kW on HP2, 7.5 kW on HP3 and HP3S, and 3 to 18.5 kW on the HPT models. Power supply is 400 V / 50 Hz / 3 AC.
Tell us about your site. Our engineering team sizes the configuration and sends a quote.