A medical oxygen purity analyser measures the oxygen concentration in the gas a PSA plant produces and, depending on the model, impurities such as carbon monoxide, carbon dioxide and moisture. The Ultra Controlo QuPHARM is a wall-mounted purity analyser for medical oxygen generation systems that measures O2, CO and CO2 at the same time, with an optional H2O transmitter.
Ask every supplier of medical oxygen purity analysers the same five questions, in writing, and compare the answers side by side.
| Check | What to ask |
|---|---|
| 1. What it measures | Which gases does it measure: oxygen only, or also CO, CO2 and moisture? |
| 2. Fixed or handheld | Is it connected to the plant, or used for spot checks? |
| 3. Sensor, alarms and outputs | Which O2 sensor does it use, and what alarms and outputs does it have? |
| 4. Calibration | How is it calibrated, and with which gas? |
| 5. Records | Are the readings recorded, and how often? |
Ask which gases the analyser measures: the oxygen concentration, and the impurities around it.
According to WHO-UNICEF (2019), oxygen analysers measure and display the concentration of oxygen in patient breathing circuits, medical gas supply lines, compressed gas cylinders and oxygen concentrators.
AIGA 113/20, the industry guide to on site generation of oxygen 93, describes two oxygen analysers that continuously monitor and record the concentrator unit output, and carbon monoxide, carbon dioxide and moisture analysers connected to the supply system control and alarm systems. The oxygen analysers shall be connected so that the main shut off valve can be automatically shut if the oxygen concentration falls outside the relevant pharmacopoeia specification.
The Global Fund briefing note on PSA plant oxygen purity (3 April 2024) says the oxygen purity range for Oxygen 93 is between 90 and 96%, often stated as 93 ± 3%.
Some documents ask for analysers connected to the plant, others for a handheld analyser, and some for both.
The Global Fund daily maintenance checklist for PSA plants records the oxygen purity (%) from the PLC and, separately, the oxygen purity (%) using a handheld oxygen analyzer. Its sustainability guidance (22 August 2024) says to monitor and record oxygen purity daily with at least two different analyzers, and that at a minimum purity should be measured daily with a handheld analyzer.
WHO-UNICEF (2019) focuses on portable handheld analysers that a biomedical engineering technician or health worker could use to test oxygen from a concentrator or from the low-pressure side of a cylinder or terminal unit source. For routine spot checks, it says alarms may not be necessary.
QuPHARM is the Ultra Controlo wall-mounted analyser for medical oxygen generation systems.
QuPHARM, launched by Ultra Controlo in 2026, monitors the purity of medical oxygen generated on site, measuring O2, CO and CO2 concentrations simultaneously, with an optional H2O transmitter. It is available with a zirconia or a paramagnetic O2 sensor.
Beyond hospital oxygen generation, the launch news lists compressed air systems, pharmaceutical production environments, and bottling and filling plants as applications.
Ask how the analyser is calibrated, and with which gas.
AIGA 113/20 (section 9.4.4) says all analysers controlling and safeguarding the oxygen 93 produced shall be calibrated periodically using a certified calibration gas and in accordance with the manufacturer’s instructions.
WHO-UNICEF (2019) says galvanic cell analysers need to be calibrated and that their sensors need to be replaced periodically.
The ULTRAOX SC datasheet lists one or two oxygen analysers with a zirconium oxide probe in the plant. Ask the manufacturer for the calibration instructions of each analyser.
Ask whether the readings are recorded, and at what interval.
AIGA 113/20 describes analysers that continuously monitor and record the concentrator unit output. The Global Fund sustainability guidance asks for oxygen purity to be monitored and recorded daily with at least two different analyzers.
Questions buyers ask about oxygen purity analysers. More on the medical gas answers page.
AIGA 113/20 describes oxygen analysers that continuously monitor and record the concentrator unit output, and carbon monoxide, carbon dioxide and moisture analysers connected to the supply system control and alarm systems.
QuPHARM is a wall-mounted medical gas purity analyser that Ultra Controlo launched in 2026 for medical oxygen generation systems. It measures O2, CO and CO2 concentrations simultaneously, with an optional H2O transmitter.
It is available with a zirconia or a paramagnetic O2 sensor.
The Global Fund sustainability guidance (22 August 2024) says to monitor and record oxygen purity daily with at least two different analyzers.
Tell us about your site. Our engineering team sizes the configuration and sends a quote.