Medical air CE 1639

How to choose a medical air plant.

Seven checks to compare medical air plants: compressor type, redundancy, capacity, air quality, certification, site and monitoring, with the ULTRAAR range as the example.

ULTRAAR ME medical air plant with compressor modules, receiver and dryer
The ULTRAAR range

Five plants, one table.

The compressor is what separates the ULTRAAR plants. Figures are as each product page states them.

PlantCompressorOilCapacityPressure
ULTRAAR ESWULTRACECO ESW piston, 1 to 8 compressorsOil-less8.4 to 120 m³/h per compressor unit, ESW 201 to 21510 or 14 bar
ULTRAAR MEULTRASCREW FSD rotary screw, 2 compressorsOil lubricated, with ULTRASEP oil/water separator22 to 1,170 Nm³/h per compressor10 or 13 bar
ULTRAAR SCULTRACECO SC scroll, 1 to 3 modulesOil-free12 to 153 Nm³/h8 or 10 bar
ULTRAAR SCAULTRACECO SCA scroll, modularOil-free9.6 to 204 m³/h8 or 10 bar
ULTRAAR SCRULTRACECO SCR dry screw, fixed or variable speedOil-less3.3 to 36.9 m³/min at 125 psig, fixed speed125 psig in the model tables
1. Compressor type

Oil-free or oil lubricated.

ULTRAAR ESW uses oil-less piston compressors, ULTRAAR SC and SCA use oil-free scroll compressors and ULTRAAR SCR uses dry screw compressors; ULTRAAR ME uses oil lubricated ULTRASCREW compressors.

In ULTRAAR ME the air treatment chain brings residual oil vapours and hydrocarbons to < 0.003 mg/m³, and ULTRASEP separates oil from the condensate before drainage.

ULTRAAR ME and oil
Datasheet
Compressors
Oil lubricated ULTRASCREW FSD
Residual oil vapours and hydrocarbons
< 0.003 mg/m³
Condensate
ULTRASEP 0 to 4 separates the oil
2. Redundancy

What happens when a unit stops.

ULTRAAR ME has redundant compressors, receivers and air treatment branches with isolation valves, which keep medical air available during maintenance or a module fault.

ULTRAAR ESW plants are designed with 1 to 8 compressors, and other configurations according to the work regime and technical specifications. HTM 02-01 (2026), the NHS England guidance, says a compressor installation should include at least two compressors.

Redundancy
Datasheets
ULTRAAR ME
2 compressors, 2 dryers, 2 air treatment chains
ULTRAAR ME dryers
Each sized for 100% of system flow
ULTRAAR ESW
1 to 8 compressors
3. Capacity and sizing

Sized to the hospital.

Each ULTRAAR product page lists its own capacity range, and the ULTRAAR ME datasheet lists every plant model with its compressor, dryer, receivers, treatment chain and separator.

The capacity of ULTRAAR ME runs from 22 to 1,170 Nm³/h per compressor at 10 bar, and from 38 to 840 Nm³/h at 13 bar, with two compressors per plant. For ULTRAAR ESW, models ESW 201 to 215 run from 8.4 to 120 m³/h per compressor unit.

ULTRAAR ME
Capacity
At 10 bar
22 to 1,170 Nm³/h per compressor
At 13 bar
38 to 840 Nm³/h per compressor
Motor power
4 to 132 kW per compressor
Air receivers
2 × 500 L to 2 × 3,000 L
4. Air quality and dew point

What the air must be.

The ULTRAAR ME datasheet gives a dew point of −40 °C to −70 °C from its ULTRADRY dryers and an air quality table with CO < 5 ppm, CO₂ < 500 ppm, SOx < 1 ppm and NOx < 2 ppm; for ULTRAAR ESW the product page gives a working dew point of −46 °C and a maximum of −70 °C.

The ULTRAAR ESW product page says its air quality is in accordance with the European Pharmacopoeia. A dedicated dew point transmitter and a dedicated CO transmitter are optional on ULTRAAR ME.

Air quality
ULTRAAR ME
Dew point
−40 °C to −70 °C
Solid particles
< 0.01 µm
Residual oil vapours and hydrocarbons
< 0.003 mg/m³
CO
< 5 ppm
CO₂
< 500 ppm
SOx and NOx
< 1 ppm and < 2 ppm
5. Certification

Standards and marking.

ULTRAAR ME is medical CE marked (CE 1639) under Directive 93/42/EEC and compliant with EN ISO 7396-1:2016, with manufacture and installation under ISO 13485:2016.

ULTRAAR ESW is constructed according to EN ISO 7396-1 and manufactured under an ISO 13485:2016 quality management system.

ULTRAAR ME
Certification
Marking
CE 1639, Directive 93/42/EEC
Pipeline standard
EN ISO 7396-1:2016
Quality system
ISO 13485:2016
Country of origin
PT (EU)
6. The site

Altitude, climate and housing.

The ULTRAAR ME datasheet has three altitude bands up to 3,000 m, an ambient temperature of +5 °C to +45 °C and a 400 V / 50 Hz / 3 AC power supply; the compressor size can increase with altitude for the same plant model.

ULTRAAR ME also comes built into a purpose-built container, a modular format Ultra Controlo describes as suitable for sites where conventional construction would be difficult, slow or disruptive.

ULTRAAR ME
Site
Altitude bands
0 to 1,000 m, 1,000 to 2,000 m, 2,000 to 3,000 m
Ambient temperature
+5 °C to +45 °C
Power supply
400 V / 50 Hz / 3 AC
Control voltage
230 V / 50 Hz / 1 AC
7. Monitoring and service

Watching the plant.

ULTRAAR ME has a touchscreen HMI with pressure and dew point, a hygrometer with remote alarm set and automatic compressor switching by operating hours.

The control panel has ModBus TCP/IP and an alarm log up to 2 GB, and an optional QuAir remote monitoring panel (4G/ETH) is available.

Control panel
ULTRAAR ME
Display
Touchscreen HMI, pressure and dew point
Dew point alarm
Hygrometer with remote alarm set
Communication
ModBus TCP/IP
Alarm log
Up to 2 GB
Remote monitoring
QuAir panel (4G/ETH), optional
Frequently asked questions

Questions about choosing a medical air plant.

More on the plants in the complete guide to medical air for hospitals.

Which compressor type should a medical air plant have?

The ULTRAAR range offers oil-less piston (ESW), oil-free scroll (SC and SCA), dry screw (SCR) and oil lubricated screw (ME) compressors.

ULTRAAR ME uses oil lubricated ULTRASCREW compressors, with an air treatment chain and an ULTRASEP oil/water separator.

Is ULTRAAR ME oil-free?

No. ULTRAAR ME uses oil lubricated ULTRASCREW compressors. The air treatment chain brings residual oil vapours and hydrocarbons to < 0.003 mg/m³, and ULTRASEP separates oil from the condensate before drainage.

How many compressors does an ULTRAAR plant have?

ULTRAAR ME has two compressors, two dryers and two air treatment chains in each plant. ULTRAAR ESW plants are designed with 1 to 8 compressors.

Does altitude change the plant?

Yes. The datasheet lists bands of 0 to 1,000 m, 1,000 to 2,000 m and 2,000 to 3,000 m, and the compressor size can increase with altitude.

What certification does ULTRAAR ME carry?

Medical CE marked (CE 1639) under Directive 93/42/EEC. It is compliant with EN ISO 7396-1:2016, with manufacture and installation under ISO 13485:2016.

Request a project assessment

Ready to discuss medical air for your hospital?

Tell us about your site. Our engineering team sizes the configuration and sends a quote.

CE 1639
ISO 13485:2016
80+ countries
40 years