Manufacturer CE 1639 · Class IIa

A manufacturer of anaesthetic gas scavenging systems.

Ultra Controlo is a Portuguese manufacturer of anaesthetic gas scavenging systems (AGSS) for hospitals. It designs ULTRASEG, assembles and tests it in its own factories in Portugal, and has systems installed in more than 80 countries.

ULTRASEG anaesthetic gas scavenging system, two units on a skid with control panel
Suction level
−0.2bar
Anaesthetic gas suction
Capacity
50 to 315m³/h
Per pump, at 50 Hz, by model
Models
12
H50 to H170 and E50 to E300
Medical device
ClassIIa
CE 1639, Directive 93/42/EEC
Countries
80+
With Ultra Controlo systems installed
At a glance

Who makes ULTRASEG.

Ultra Controlo is a Portuguese company that designs and manufactures medical gas systems for hospitals.

In Portugal: Ultra Controlo designs its systems and assembles and tests every product in its own factories there.

Ultra Controlo
Company profile
Company
Ultra-Controlo Projectos Industriais, Lda.
Headquarters
Avenida dos Combatentes 52, Abrunheira, 2710-034 Sintra, Portugal
AGSS range
ULTRASEG, 12 models from H50 to E300
Medical device
CE 1639, Class IIa (Directive 93/42/EEC)
Built to
EN ISO 7396-2
Quality system
ISO 13485:2016 and ISO 9001:2015
Installed in
More than 80 countries
Experience
40 years
What an AGSS is

A scavenging system, not a vacuum.

AGSS stands for anaesthetic gas scavenging system: the system that captures waste anaesthetic gases from the patient’s breathing circuit and removes them from the operating room, protecting staff from long-term exposure.

Medical vacuum provides clinical suction at a stronger vacuum, while an AGSS removes anaesthetic gases at a much lower suction level, and its disposal system has its own standard, EN ISO 7396-2. Clinical vacuum runs at −0.75 to −0.85 bar. Anaesthetic gas scavenging runs at −0.2 bar.

What does AGSS stand for?

Is an AGSS the same as medical vacuum?

Active or passive AGSS

How ULTRASEG works

From the breathing circuit to the pumps.

ULTRASEG is an active system based on suction of anaesthetic gas mixtures from operating rooms and others fitted with nitrous oxide terminal units.

01

Receiver unit

The anaesthetic breathing circuit is connected via a receiver unit to the terminal unit.

02

Terminal unit

The terminal unit is generally installed close to the point of use. Its adjustable orifice allows the flow to be set for high-flow and low-flow systems.

03

Side channel pumps

Fully dry running, air cooled side channel vacuum blowers draw the gas mixtures at −0.2 bar. In the duplex version one pump runs while the other stands by.

Capacity

Twelve models, H50 to E300.

Each pump delivers 50 to 315 m³/h at 50 Hz, depending on the model. Power supply is 400 V / 50 Hz / 3 AC, and weights are given for simplex and duplex.

ModelCapacity m³/h, 50 HzMotor kWWeight simplex kgWeight duplex kg
ULTRASEG H50500.5561112
ULTRASEG H65650.5562114
ULTRASEG H90901.177124
ULTRASEG H1201201.584138
ULTRASEG H1701702.289148
ULTRASEG E50500.25498
ULTRASEG E80790.455100
ULTRASEG E1001030.456102
ULTRASEG E1401430.8558106
ULTRASEG E1801801.363116
ULTRASEG E2002101.668126
ULTRASEG E3003152.272134

Other voltages and frequencies are available according to the country regulations, and other capacities on request.

Layouts and control

SIMPLEX, DUPLEX and TRIPLEX.

Standard layouts SIMPLEX, DUPLEX and TRIPLEX, with a Manual/Stop/Auto selector and a run and fault indicator light per pump.

ULTRASEG is delivered fully connected and pre-assembled, with interconnecting cables and hoses in place, parameterised and factory tested.

How do staff know an AGSS has failed?

ULTRASEG
Specification
Suction level
−0.2 bar
Capacity per pump
50 to 315 m³/h, see the model table
Motor power
0.2 to 2.2 kW per pump
Suction set
Vacuum regulator with spring-loaded plate, suction non-return valve, intake silencer, 5 µm suction filter with 99.9% efficiency
Control panel
Digital vacuum controller and level display, remote interface for OT terminal units, Modbus TCP/IP
Alarms
Visual and audible alarms, low pipeline vacuum alarms, potential-free contacts, alarm log capacity 2 to 8 GB
Options
Variable speed by frequency converter, QuVac remote monitoring panel (4G/ETH)
Made in Portugal

A manufacturer, not a reseller.

Tested before it ships.

ULTRASEG arrives pre-assembled, set up and tested in the factory. On medium and large plants, factory technicians supervise commissioning and staff training.

A pump on standby.

In the duplex version one pump runs while the other stands by.

Light routine care.

Up to 20,000 operating hours between services. Preventive care is typically an annual inspection, with occasional replacement of the suction-side filter element.

Certification

Built to EN ISO 7396-2.

ULTRASEG complies with EN ISO 7396-2, Medical gas pipeline systems, Part 2: Anaesthetic gas scavenging disposal systems.

It is Medical CE marked (CE 1639) under Directive 93/42/EEC as a Class IIa medical device, and produced under ISO 13485:2016 and ISO 9001:2015.

ISO 7396-2: anaesthetic gas scavenging disposal systems

ULTRASEG
Standards and certification
Standard
EN ISO 7396-2
Guidance
HTM 02-01, the NHS England guidance
Certification
Medical CE marked (CE 1639), Directive 93/42/EEC, Class IIa
Quality system
ISO 13485:2016 and ISO 9001:2015
Country of origin
PT (EU)
Real-world deployment

Installed with the full gas system.

In Cabo Verde, Ultra Controlo installed anaesthetic gas scavenging together with medical vacuum, medical air, nitrous oxide and the full medical gas pipeline.

CV
August 2026
Cabo Verde · Praia

The President of Portugal visits the oxygen plant at Hospital Dr. Agostinho Neto

During his State visit to Cabo Verde in July, the President of the Portuguese Republic, António José Seguro, visited the Dr. Agostinho Neto Hospital in Praia, the largest hospital in the country. Oxygen is only part of the work. Ultra Controlo also installed medical vacuum, medical air, anaesthetic gas scavenging, nitrous oxide and the full medical gas pipeline that carries these gases to every point of care throughout the hospital.

Anaesthetic gas scavenging Read the story
Frequently asked questions

Questions buyers ask an AGSS manufacturer.

Questions hospitals ask us about anaesthetic gas scavenging. More on the medical gas answers page.

Is Ultra Controlo a manufacturer or a distributor of anaesthetic gas scavenging systems?

Ultra Controlo is the manufacturer. It designs ULTRASEG and assembles and tests it in its own factories in Portugal.

What is ULTRASEG?

ULTRASEG is an active anaesthetic gas scavenging system for the extraction and elimination of waste anaesthetic gases. It is manufactured in accordance with EN ISO 7396-2 and built in accordance with HTM 02-01, with fully dry running, air cooled side channel vacuum blowers using Elmo Rietschle technology.

What does AGSS stand for?

Anaesthetic gas scavenging system: it captures waste anaesthetic gases from the patient’s breathing circuit and removes them from the operating room, protecting staff from long-term exposure. Ultra Controlo’s AGSS is ULTRASEG, with Elmo Rietschle side channel pumps from the H50 and E50 (50 m³/h) to the E300 (315 m³/h at 50 Hz), at −0.2 bar.

Is AGSS the same as medical vacuum?

No. Medical vacuum provides clinical suction at a stronger vacuum, while an AGSS removes anaesthetic gases at a much lower suction level, under its own standard, EN ISO 7396-2. ULTRAVAC works at −0.75 to −0.85 bar and ULTRASEG at −0.2 bar.

What capacities does ULTRASEG cover?

Each pump delivers 50 to 315 m³/h at 50 Hz depending on the model, from the H50 and E50 to the E300, at −0.2 bar, with motors of 0.2 to 2.2 kW. There are 12 models, in SIMPLEX, DUPLEX and TRIPLEX layouts. Other capacities are available on request.

Is ULTRASEG CE marked?

Yes. It is Medical CE marked (CE 1639) under Directive 93/42/EEC as a Class IIa medical device, and produced under ISO 13485:2016 and ISO 9001:2015.

How do I get a quote or ask an engineer?

Email leads@ultra-controlo.com or call +351 219 154 350 with the site, the rooms to serve and the number of terminal units.

Request a project assessment

Ready to discuss anaesthetic gas scavenging for your hospital?

Tell us about your site. Our engineering team sizes the configuration and sends a quote.

CE 1639
Class IIa
ISO 13485:2016
80+ countries
40 years