Second Stage Units, Without Area Valve

Reducer Without Area Valve

The 2nd stage unit is made of cast chemically nickel-plated brass; the regulator body has two decompression lines with two regulators connected in by-pass through four ball valves, two on the inlet and two on the outlet of the same.

Reducer Without Area Valve
Specifications

What it is made of.

Features

  • Two regulators in by-pass
  • Four isolation ball valves
  • Upstream and outlet pressure gauges

Components

  • 1 × regulator body made of cast CW614N chemically nickel-plated brass
  • 1 × Ø16 mm weld-on pipe inlet connection
  • 1 × Ø16 mm weld-on pipe outlet connection
  • 1 × stainless steel filter
  • 2 × shut-off valves upstream of each regulator with check valves
  • 2 × shut-off valves downstream of each regulator with check valves
  • 1 × emergency gas-specific socket
  • 1 × block for physical disconnection
  • 1 × pressure gauge to show system pressure, range 0-16 bar, class 2.5
  • 1 × pressure gauge with contacts that measures the outlet pressure, range 0-16 bar, with 3.8 bar and 5.6 bar threshold
  • Stainless steel springs
  • EPDM PEROX membrane
  • VULKOLLAN regulator seat ring
  • EPDM PEROX O-Ring

Standards

  • EN ISO 10524-2 (Pressure regulators for use with medical gases: Part 2: Manifold and line pressure regulators)
  • EN ISO 7396-1 (Medical gas pipeline systems: Part 1: Pipeline systems for compressed medical gases and vacuum)
  • NF S 90-116 (Medical gas pipeline distribution systems: Sockets and related probes for medical fluids: Design and installation)
  • UNI 9507 (Medical gases pipeline systems: Terminal units)
  • EN ISO 15001 (Anaesthetic and respiratory equipment: compatibility with oxygen)
  • EN ISO 18082 (Anaesthetic and respiratory equipment: Dimensions of non-interchangeable screw-threaded (NIST) low-pressure connectors for medical gases)

Versions 10

GasSocketØ inlet - outletQ max.P1 max.P2Weight
O2AFNOR NF S 90-11616 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
O2NIST ISO 1808216 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
N2OAFNOR NF S 90-11616 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
N2ONIST ISO 1808216 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
Air 400AFNOR NF S 90-11616 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
Air 400NIST ISO 1808216 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
Air 800NIST ISO 1808216 mm - 16 mm50 Nm³/h10 bar8 bar6.00 kg
CO2AFNOR NF S 90-11616 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
CO2NIST ISO 1808216 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg
N2AFNOR NF S 90-11616 mm - 16 mm30 Nm³/h10 bar4.5 bar6.00 kg

All variants: 6.00 kg.

Datasheet

The full datasheet, in four languages.

Need this for a project?

Tell us the gases, the quantities and the outlet standard you use. Our engineers reply with a proposal.

Request a quote