Industry Solutions

Industry · Marine

Marine. Starting air, receivers and seawater pumps.

Ships with air-started diesel engines need starting air receivers sized for at least twelve starts of each reversible main engine, or six of a non-reversible one, according to UK Maritime and Coastguard Agency surveyor instructions and Canadian vessel regulations. Ultra Controlo distributes and services two partner brands whose makers name ships and seawater: Speck Pumpen (Circutec) side channel pumps and Speck Triplex seawater plunger pumps.

Container ship at sea, seen from above
01
12starts
Each reversible main engine, from the receiver, per UK MCA
02
6starts
Each non-reversible main engine, per UK MCA
03
3starts
Stored for an auto-started emergency generator, per Transport Canada
04
2×
Hydraulic test of air pipes vs maximum working pressure, per UK MCA
Where the air goes

Compressed air in the engine room.

The UK Maritime and Coastguard Agency instructions for passenger ships of Classes III to VI(A), Canada's Large Fishing Vessel Inspection Regulations and Transport Canada's study guide for marine engineers describe these uses.

Starting

Starting the main engines

Diesel engines that need compressed air for starting draw it from a starting air receiver that is kept fully charged and ready for use.

Compressors

Two starting air compressors

At least one starting air compressor, plus one that can be put into operation without external aid when no compressed air is on board, unless the first one can.

Emergency

Emergency generator starting

Compressed air starting of the emergency generator may be kept up from the main or auxiliary receivers through a non-return valve, or by an emergency air compressor.

Receivers

Drains, relief valves, fusible plugs

Air receivers need efficient drains and relief valves; a receiver that can be isolated from its relief valves needs a fusible plug to discharge its contents in a fire.

Piping

Oil-free, flame-protected pipes

The inside of air pressure pipes is kept free from oil and protected from flame from the cylinders or from an internal explosion; an isolating non-return valve sits at the inlet of the starting air manifold.

Compressors

Draining water and oil

Means for draining water and oil are fitted at each interstage and final discharge pipe of the air compressors.

Sources: UK Maritime and Coastguard Agency, Passenger ship construction, classes III to VI(A) (MSIS 4), Part VIII, sections 8.1.3 and 8.1.9; Canada, Large Fishing Vessel Inspection Regulations (C.R.C., c. 1435), section 13, current to 30 September 2026; Transport Canada, TP 14609, section 5.

Starting air

How much air the receiver holds.

Three published texts size the starting reserve by the number of starts it must give, not by volume.

Main engines, UK MCA

12 or 6 starts

The starting air receiver should start each main engine at least twelve times where the engines are reversible, or six times where they are non-reversible; the number of starts and the lowest starting pressure should be recorded.

Source: UK MCA, MSIS 4, Part VIII, 8.1.3.1.

Main engines, Canada

Without replenishment

Where main engines depend on compressed air for starting, receiver capacity must allow 12 consecutive starts of reversible engines or six of non-reversible engines without replenishment, with one compressor driven by a prime mover that starts without compressed air.

Source: C.R.C., c. 1435, section 13(3).

Emergency generator

3 starts, then 3 more

An automatically started emergency generating set needs stored energy for at least three consecutive starts, and a second source for three more within 30 minutes, unless manual starting is shown to be effective.

Source: Transport Canada, TP 14609, section 5.

These texts cover UK domestic passenger ships, Canadian large fishing vessels and the Transport Canada engineer syllabus; check the rules that apply to each ship.

What we supply

Pumps for seawater, equipment for the air on board.

Equipment from the partner brands we supply, matched to the jobs on ships. Where a maker names ships or seawater, the card says so; otherwise the match is our recommendation, and the Ultra Controlo catalogue does not list marine starting air compressors.

Water transfer

Speck Pumpen (Circutec) side channel pumps

For salt and fresh water on ships, we supply self-priming side channel pumps that handle entrained gas and are rated PN 40, according to Circutec; Speck Pumpen brochures list SKM and ASKM versions to ATEX II 2G (ATEX Directive 2014/34/EU marking: equipment group II, category 2, atmospheres caused by gases, vapours or mists) and the delivery of salt and fresh water in ships.

Speck Pumpen
Seawater

Speck Triplex stainless and seawater plunger pumps

For seawater on board, we supply plunger pumps in seawater versions such as the P80/400-140S, which Speck Triplex rates at up to 400 l/min for clean water, seawater and other non-abrasive media of a similar specific weight.

Speck Triplex
Desalination

Speck Triplex high-pressure units

For seawater desalination, we supply units built to the customer’s specification; Speck Triplex offers them in NiAlBz for seawater, lists seawater desalination and shows a reverse osmosis desalination unit.

Speck Triplex
Water on board

Speck piston pumps PM, BS, S and HS

For water supply on ships, we supply Speck piston pumps: the S series delivers up to 45,000 l/h and the HS series reaches up to 40 bar, says Speck Triplex, which lists ships among their uses.

Speck Triplex
Starting air

Gardner Denver high-pressure and high-temperature filters

For keeping oil out of starting air lines, we supply high-pressure filters that Gardner Denver rates for 1.8 to 41.6 m³/min at up to 45 bar.

Gardner Denver
Cooling water

SPECK (Neunkirchen) Normblock pumps

For cooling water on board, we supply close-coupled single-stage volute casing pumps in cast iron, which SPECK (Neunkirchen) rates at up to 600 m³/h and 100 m head and lists for shipbuilding.

Speck Pumpen

Sources: Ultra Controlo Industrial 2026 catalogue, pp. 13 and 14; Speck Pumpen, side channel pumps and process industry brochures (speck.de); Circutec, side channel pumps (circutec.de); Speck Triplex, seawater version, R-Versions, systems, fields of use and piston pumps pages (speck-triplex.de); Gardner Denver, GDF Series and GDWS Range filter brochure 2026; SPECK Pumpen (Neunkirchen), Product overview 03/25 (PDF), p. 2, and Normblock product pages.

One supplier. Made and serviced in Portugal.

Ultra Controlo is a Portuguese manufacturer of compressed air, vacuum and technical gas systems, with 40 years of experience. We design, assemble and test our own compressors, dryers and carbon towers in Portugal, and supply and service five partner brands.

Our own lines

ULTRASCREW compressors, ULTRASEC and ULTRADRY dryers and ULTRAK activated carbon towers.

Five partner brands

Gardner Denver, Elmo Rietschle, Thomas, Speck Pumpen (Circutec and SPECK Neunkirchen) and Speck Triplex.

UltraCare, 24/7

Preventive and corrective maintenance, original spare parts and emergency support, by our own team.

Source: Ultra Controlo Industrial 2026 catalogue, pp. 3, 10, 16, 17 and 22.

Questions

Marine: questions and answers.

How many starts must a ship's starting air receiver hold?

UK MCA instructions for passenger ships of Classes III to VI(A) say at least twelve starts of each reversible main engine, or six of a non-reversible one. Canada's Large Fishing Vessel Inspection Regulations set the same 12 and six, without replenishment of the air.

What do the rules say about oil in starting air pipes?

The UK MCA instructions say provision should be made to keep the interior of air pressure pipes free from oil, and either to prevent flame passing from the engine cylinders into the pipes or to protect the pipes from an internal explosion.

What starting reserve does an emergency generator need?

Transport Canada's TP 14609 study guide says an automatically started emergency generating set needs stored energy for at least three consecutive starts, and a second source for three more starts within 30 minutes, unless manual starting is shown to be effective.

What does Ultra Controlo supply for ships?

Ultra Controlo distributes and services Speck Pumpen (Circutec), whose side channel pump brochure lists delivery of salt and fresh water in ships, and Speck Triplex, which makes seawater versions of its high-pressure plunger pumps, seawater desalination units and piston pumps it lists for ships. For starting air lines, Ultra Controlo recommends Gardner Denver high-pressure filters, and for cooling water, SPECK (Neunkirchen) Normblock pumps, which the maker lists for shipbuilding.

Tell us about the vessel.

The water you pump, the flow, the pressure and the duty. We reply with what fits from the partner brands we distribute and service.