Industrial gases. Air compression, purification and on-site oxygen.

A cryogenic air separation unit compresses air in its main air compressor to between 4 and 10 atm, then removes water, carbon dioxide and heavy hydrocarbons before distillation, according to EIGA Doc 147/22, the safe practices guideline for cryogenic air separation plants that the industrial gas associations publish together with CGA P-8. Ultra Controlo supplies the ULTRAOX VSA plant, which makes oxygen on site and can replace cryogenic systems with liquid oxygen tanks, and distributes and services Gardner Denver oil-free compressors.

Stainless steel vessel lifted by an overhead crane in a fabrication hall
01
4–10atm
Main air compressor pressure in a cryogenic ASU, per EIGA Doc 147/22
02
99.9%
Maximum purity of delivered liquid oxygen, per Nickerson (2008)
03
5%/day
Approximate maximum loss of stored liquid oxygen to evaporation, per WHO medical oxygen guidance (2023)
04
75–95%
Oxygen from ULTRAOX VSA, at 50 kPa
From air to gas

Six steps and machines in gas production.

The safe practices guideline for cryogenic air separation plants (EIGA Doc 147/22, harmonised with CGA P-8) and the US Department of Energy sourcebook (2016) describe these steps.

Compression

Main air compressor

Air is compressed to between 4 and 10 atm and cooled to ambient; axial compressors are common on large units, and centrifugal compressors are widely used for this duty.

Purification

Prepurification

A prepurification unit with molecular sieve and alumina, or a reversing heat exchanger, removes water, carbon dioxide and heavy hydrocarbons from the air.

Cold box

Heat exchange and distillation

The main exchanger cools the air to near liquefaction, high and low pressure columns separate oxygen, nitrogen and argon, and an expander provides refrigeration.

Products

Product compressors

Centrifugal compressors serve oxygen and nitrogen product duty; reciprocating compressors are widely used for oxygen, nitrogen, crude argon and high pressure air.

Intake

Clean intake air

The compressor intake is kept away from contaminant sources such as engine exhausts and vents; prepurifier dust filters typically capture particles of 2 to 5 microns and larger.

Membranes

Membrane nitrogen

Oxygen permeates a membrane faster than nitrogen, leaving nitrogen at the outlet; the DOE cites nitrogen production for food storage.

Sources: EIGA Doc 147/22, Guideline for safe practices for cryogenic air separation plants (European Industrial Gases Association, harmonised with CGA P-8), sections 3, 7 and 8; US DOE and Compressed Air Challenge, Improving Compressed Air System Performance (2016), p. 13.

Oil and air quality

Keeping oil out of the cold box.

The EIGA guideline sets out how compressor type and lubrication affect the air that reaches the separation process.

Screw compressors

Oil-lubricated or not

Oil-lubricated screw compressors need separators followed by filters, coalescers, adsorptive beds or a combination, maintained for complete oil removal; this is particularly critical when the screw is the main air compressor.

Source: EIGA Doc 147/22, section 8.8.

Reciprocating

Tolerance to oil

The tolerance of the gas to oil contamination is one of the factors in choosing between nonlubricated and lubricated cylinder compressors.

Source: EIGA Doc 147/22, section 8.4.

Haze

Filters of 0.1 to 0.4 µm

Where aerosols from haze can exceed design limits, a high efficiency filter removing particles larger than 0.1 to 0.4 µm can be placed on the compressor inlet or the prepurifier outlet.

Source: EIGA Doc 147/22, section 7.5.

Oil carryover from the main air compressor would foul the cold box, the guideline notes. Source: EIGA Doc 147/22, harmonised with CGA P-8.

Delivered or made on site

Liquid oxygen or an on-site VSA plant.

The comparison draws on Nickerson (2008), Losordo (2014), a 2001 US DOE paper and the ULTRAOX VSA datasheet.

Sources: P. Nickerson and T. M. Losordo, Global Aquaculture Advocate (2008, 2014); E. Levine and K. Jamison, ACEEE (2001); ULTRAOX VSA datasheet, pp. 2 and 3.
CriterionDelivered liquid oxygenOn-site VSA
PurityUp to 99.9% (Nickerson, 2008)ULTRAOX VSA: 75% to 95% at 50 kPa (datasheet)
ElectricityNot required; delivered by its own pressure (Nickerson, 2008)Needed; the reliability of the electrical service is a selection factor (Losordo, 2014)
PressureDelivered by its own pressure (Nickerson, 2008)ULTRAOX VSA: 50 kPa; higher pressures with an additional oxygen booster supplied on demand (datasheet)
Cost factors citedThe price of liquid oxygen, which usually depends on the distance from the production plant (Losordo, 2014)Electricity cost (DOE, 2001) and the reliability of the electrical service (Losordo, 2014)
What we supply

On-site oxygen, oil-free air and pumps for gases.

Equipment we make, and equipment from the partner brands we supply, matched to the jobs in industrial gas production. Where a maker names the industry, the card says so; otherwise the match is our recommendation.

Oxygen on site

ULTRAOX VSA oxygen plant

75% to 95% oxygen at 50 kPa, on a skid or in a container; the datasheet says it can replace cryogenic systems with liquid oxygen tanks or work as the main source of supply.

ULTRAOX VSA
No oil in

Gardner Denver EnviroAire T/TVS

To keep compressor oil out of the feed air, we supply two-stage dry screw compressors certified ISO 8573-1 (Compressed air: contaminants and purity classes) Class 0 by TÜV; the T/TVS 90-160 gives 6.7 to 28.3 m³/min and 7.5 to 10.5 bar, says Gardner Denver.

Gardner Denver
Oil vapour out

ULTRAK activated carbon towers

An adsorptive stage that removes oil vapours from compressed air to below 0.003 mg/m³, with a coalescing filter required upstream.

ULTRAK
Coalescing filters

Gardner Denver GDF filters and GDWS separators

For the filters and coalescers after an oil-lubricated compressor, we supply GDF filters: grade H removes particles down to 0.01 micron and leaves at most 0.01 mg/m³ of oil aerosol at 21 °C, says Gardner Denver.

Gardner Denver
CO2 filling

Speck Triplex CO2 plunger pumps

For bottle and vessel filling, which Speck Triplex lists for its CO2 pumps, we supply plunger pumps that also circulate supercritical CO2 up to 300 bar; the pump compressor moves gaseous CO2 oil-free against a vessel pressure of up to 70 bar, says Speck Triplex.

Speck Triplex
Lab generators and analysers

Thomas WOB-L® piston pumps

For laboratory equipment such as nitrogen generators and gas analysers, which Thomas names among the uses of its piston pumps, we supply these oil-free, dry running pumps; one WOB-L® series gives up to 212.4 l/min, 12.1 bar or −980 mbar, says Thomas.

Thomas

Sources: ULTRAOX VSA datasheet, pp. 2 and 3; Ultra Controlo Industrial 2026 catalogue, pp. 12 and 19; ULTRAK datasheet; Gardner Denver, EnviroAire T/TVS 90-160kW page, Air Compressor Filters (EMEIA) and GDF Series and GDWS Range filter brochure; Speck Triplex, CO2 versions; Thomas, piston pumps technology page, piston pumps and compressors page and WOB-L 2755 Series page.

One supplier. Made and serviced in Portugal.

Ultra Controlo is a Portuguese manufacturer of compressed air, vacuum and technical gas systems, with 40 years of experience. We design, assemble and test our own compressors, dryers and carbon towers in Portugal, and supply and service five partner brands.

Our own lines

ULTRASCREW compressors, ULTRASEC and ULTRADRY dryers and ULTRAK activated carbon towers.

Five partner brands

Gardner Denver, Elmo Rietschle, Thomas, Speck Pumpen (Circutec and SPECK Neunkirchen) and Speck Triplex.

UltraCare, 24/7

Preventive and corrective maintenance, original spare parts and emergency support, by our own team.

Source: Ultra Controlo Industrial 2026 catalogue, pp. 3, 10, 16, 17 and 22.

Questions

Industrial gases: questions and answers.

What does the main air compressor of an air separation unit do?

The safe practices guideline for cryogenic air separation plants (EIGA Doc 147/22, harmonised with CGA P-8) says air is compressed in the main air compressor to between 4 atm and 10 atm and cooled, before water, carbon dioxide and heavy hydrocarbons are removed ahead of the cold box.

Can an oil-lubricated screw compressor feed an air separation unit?

EIGA Doc 147/22 says oil-lubricated screw compressors need downstream oil removal, typically separators followed by filters, coalescers or adsorptive beds, maintained to ensure complete removal; this is particularly critical when the screw is the main air compressor.

Can plant instrument air be used as breathing air?

No. The safe practices guideline for cryogenic air separation plants (EIGA Doc 147/22) states that breathing air should come from a verified source and that a plant instrument air system shall not be used as a source of breathing air.

Can a VSA plant replace delivered liquid oxygen?

The ULTRAOX VSA datasheet says the plant can replace existing cryogenic systems with liquid oxygen tanks or work as the main source of supply, at 75% to 95% oxygen and 50 kPa; delivered liquid oxygen is up to 99.9% pure (Nickerson, 2008).

How does a membrane make nitrogen?

The US Department of Energy sourcebook (2016) explains that molecules such as oxygen permeate a semi-permeable membrane faster than nitrogen, leaving a concentration of nitrogen at the outlet of the generator; it cites nitrogen production for food storage.

What does Ultra Controlo supply for industrial gas production?

Ultra Controlo makes the ULTRAOX VSA oxygen plant for oxygen on site and ULTRAK carbon towers, which remove oil vapour. Ultra Controlo also recommends Gardner Denver EnviroAire T/TVS oil-free compressors and GDF filters for the feed air, Speck Triplex plunger pumps for CO2 filling, and Thomas WOB-L piston pumps, which the maker names for laboratory nitrogen generators and gas analysers.

Tell us about your gas supply.

The gas, the purity and pressure you need, the flow and how you are supplied today. We reply with the equipment that fits.