A cryogenic air separation unit compresses air in its main air compressor to between 4 and 10 atm, then removes water, carbon dioxide and heavy hydrocarbons before distillation, according to EIGA Doc 147/22, the safe practices guideline for cryogenic air separation plants that the industrial gas associations publish together with CGA P-8. Ultra Controlo supplies the ULTRAOX VSA plant, which makes oxygen on site and can replace cryogenic systems with liquid oxygen tanks, and distributes and services Gardner Denver oil-free compressors.
Main air compressor pressure in a cryogenic ASU, per EIGA Doc 147/22
02
99.9%
Maximum purity of delivered liquid oxygen, per Nickerson (2008)
03
5%/day
Approximate maximum loss of stored liquid oxygen to evaporation, per WHO medical oxygen guidance (2023)
04
75–95%
Oxygen from ULTRAOX VSA, at 50 kPa
From air to gas
Six steps and machines in gas production.
The safe practices guideline for cryogenic air separation plants (EIGA Doc 147/22, harmonised with CGA P-8) and the US Department of Energy sourcebook (2016) describe these steps.
Compression
Main air compressor
Air is compressed to between 4 and 10 atm and cooled to ambient; axial compressors are common on large units, and centrifugal compressors are widely used for this duty.
Purification
Prepurification
A prepurification unit with molecular sieve and alumina, or a reversing heat exchanger, removes water, carbon dioxide and heavy hydrocarbons from the air.
Cold box
Heat exchange and distillation
The main exchanger cools the air to near liquefaction, high and low pressure columns separate oxygen, nitrogen and argon, and an expander provides refrigeration.
Products
Product compressors
Centrifugal compressors serve oxygen and nitrogen product duty; reciprocating compressors are widely used for oxygen, nitrogen, crude argon and high pressure air.
Intake
Clean intake air
The compressor intake is kept away from contaminant sources such as engine exhausts and vents; prepurifier dust filters typically capture particles of 2 to 5 microns and larger.
Membranes
Membrane nitrogen
Oxygen permeates a membrane faster than nitrogen, leaving nitrogen at the outlet; the DOE cites nitrogen production for food storage.
Sources: EIGA Doc 147/22, Guideline for safe practices for cryogenic air separation plants (European Industrial Gases Association, harmonised with CGA P-8), sections 3, 7 and 8; US DOE and Compressed Air Challenge, Improving Compressed Air System Performance (2016), p. 13.
Oil and air quality
Keeping oil out of the cold box.
The EIGA guideline sets out how compressor type and lubrication affect the air that reaches the separation process.
Screw compressors
Oil-lubricated or not
Oil-lubricated screw compressors need separators followed by filters, coalescers, adsorptive beds or a combination, maintained for complete oil removal; this is particularly critical when the screw is the main air compressor.
Source: EIGA Doc 147/22, section 8.8.
Reciprocating
Tolerance to oil
The tolerance of the gas to oil contamination is one of the factors in choosing between nonlubricated and lubricated cylinder compressors.
Source: EIGA Doc 147/22, section 8.4.
Haze
Filters of 0.1 to 0.4 µm
Where aerosols from haze can exceed design limits, a high efficiency filter removing particles larger than 0.1 to 0.4 µm can be placed on the compressor inlet or the prepurifier outlet.
Source: EIGA Doc 147/22, section 7.5.
Oil carryover from the main air compressor would foul the cold box, the guideline notes. Source: EIGA Doc 147/22, harmonised with CGA P-8.
Delivered or made on site
Liquid oxygen or an on-site VSA plant.
The comparison draws on Nickerson (2008), Losordo (2014), a 2001 US DOE paper and the ULTRAOX VSA datasheet.
Sources: P. Nickerson and T. M. Losordo, Global Aquaculture Advocate (2008, 2014); E. Levine and K. Jamison, ACEEE (2001); ULTRAOX VSA datasheet, pp. 2 and 3.
Criterion
Delivered liquid oxygen
On-site VSA
Purity
Up to 99.9% (Nickerson, 2008)
ULTRAOX VSA: 75% to 95% at 50 kPa (datasheet)
Electricity
Not required; delivered by its own pressure (Nickerson, 2008)
Needed; the reliability of the electrical service is a selection factor (Losordo, 2014)
Pressure
Delivered by its own pressure (Nickerson, 2008)
ULTRAOX VSA: 50 kPa; higher pressures with an additional oxygen booster supplied on demand (datasheet)
Cost factors cited
The price of liquid oxygen, which usually depends on the distance from the production plant (Losordo, 2014)
Electricity cost (DOE, 2001) and the reliability of the electrical service (Losordo, 2014)
What we supply
On-site oxygen, oil-free air and pumps for gases.
Equipment we make, and equipment from the partner brands we supply, matched to the jobs in industrial gas production. Where a maker names the industry, the card says so; otherwise the match is our recommendation.
Sources: ULTRAOX VSA datasheet, pp. 2 and 3; Ultra Controlo Industrial 2026 catalogue, pp. 12 and 19; ULTRAK datasheet; Gardner Denver, EnviroAire T/TVS 90-160kW page, Air Compressor Filters (EMEIA) and GDF Series and GDWS Range filter brochure; Speck Triplex, CO2 versions; Thomas, piston pumps technology page, piston pumps and compressors page and WOB-L 2755 Series page.
One supplier. Made and serviced in Portugal.
Ultra Controlo is a Portuguese manufacturer of compressed air, vacuum and technical gas systems, with 40 years of experience. We design, assemble and test our own compressors, dryers and carbon towers in Portugal, and supply and service five partner brands.
Our own lines
ULTRASCREW compressors, ULTRASEC and ULTRADRY dryers and ULTRAK activated carbon towers.
Five partner brands
Gardner Denver, Elmo Rietschle, Thomas, Speck Pumpen (Circutec and SPECK Neunkirchen) and Speck Triplex.
UltraCare, 24/7
Preventive and corrective maintenance, original spare parts and emergency support, by our own team.
Source: Ultra Controlo Industrial 2026 catalogue, pp. 3, 10, 16, 17 and 22.
Questions
Industrial gases: questions and answers.
What does the main air compressor of an air separation unit do?
The safe practices guideline for cryogenic air separation plants (EIGA Doc 147/22, harmonised with CGA P-8) says air is compressed in the main air compressor to between 4 atm and 10 atm and cooled, before water, carbon dioxide and heavy hydrocarbons are removed ahead of the cold box.
Can an oil-lubricated screw compressor feed an air separation unit?
EIGA Doc 147/22 says oil-lubricated screw compressors need downstream oil removal, typically separators followed by filters, coalescers or adsorptive beds, maintained to ensure complete removal; this is particularly critical when the screw is the main air compressor.
Can plant instrument air be used as breathing air?
No. The safe practices guideline for cryogenic air separation plants (EIGA Doc 147/22) states that breathing air should come from a verified source and that a plant instrument air system shall not be used as a source of breathing air.
Can a VSA plant replace delivered liquid oxygen?
The ULTRAOX VSA datasheet says the plant can replace existing cryogenic systems with liquid oxygen tanks or work as the main source of supply, at 75% to 95% oxygen and 50 kPa; delivered liquid oxygen is up to 99.9% pure (Nickerson, 2008).
How does a membrane make nitrogen?
The US Department of Energy sourcebook (2016) explains that molecules such as oxygen permeate a semi-permeable membrane faster than nitrogen, leaving a concentration of nitrogen at the outlet of the generator; it cites nitrogen production for food storage.
What does Ultra Controlo supply for industrial gas production?
Ultra Controlo makes the ULTRAOX VSA oxygen plant for oxygen on site and ULTRAK carbon towers, which remove oil vapour. Ultra Controlo also recommends Gardner Denver EnviroAire T/TVS oil-free compressors and GDF filters for the feed air, Speck Triplex plunger pumps for CO2 filling, and Thomas WOB-L piston pumps, which the maker names for laboratory nitrogen generators and gas analysers.